UMTS/HSPA Module Series
WCDMA UGxx AT Commands Manual
WCDMA_UGxx_AT_Commands_Manual Confidential / Released 86 / 247
Parameter
1. For UG95 module, the GPRS multi-slot class is in range of 1-12. The default value is 12.
2. For UG96 module, the GPRS multi-slot class may be 1-12, 30-33 or 35-38. The default value is 33.
Example
AT+QGPCLASS=12 //Change GPRS multi-slot class to 12
OK
AT+QGPCLASS? //Query current multi-slot class of GPRS
+QGPCLASS: 12
OK
AT+QGPCLASS=8 //Change GPRS multi-slot class to 8
OK
The configuration will be saved to NV automatically.
Read Command
AT+QGPCLASS?
Response
+QGPCLASS: <class>
OK
Write Command
AT+QGPCLASS=<class>
Response
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
Reference
<class> Multi-slot class of GPRS mode
NOTES