Default: [2]
The vacuum level can be set from 1 to 9, using the number keys.
Test Feed
Perform test feeding to check whether the configured heater temperature is appropriate for the media to
be used.
Rewind or not? (after test feeding)
• Yes
• No
Continuous Print Margin
When printing an image continuously, specify the print margin between each image according to the
media to be used and the configured temperature of the heaters. If the pre-heater, print heater, and
post-heater have the same temperature setting, you can reduce the amount of media used by reducing
the print margin. Shrinking the margins can reduce the amount of media required. However, media will
be rewound between jobs, possibly resulting in reduced print quality.
(mainly Europe and Asia)
Default: [160 mm]
The continuous print margin can set from 15 to 160 mm, using the number keys.
(mainly North America)
Default: [6.3 inch]
The continuous print margin can set from 0.6 to 6.3 inches, using the number keys.
[Heater Settings] Screen
This section explains the setting items and default values on the [Heater Settings] screen.
Pre
Specify whether to enable the pre-heater. When selecting the [On] check box, the heater is
enabled and preheats media so that consistent print quality can be maintained.
Default: [Disable]
(mainly Europe and Asia)
Default: [60°C]
When you select the [On] check box, the temperature can be set from 20 to 70°C, using [ ] or
[ ].
(mainly North America)
List of Setting Items
149