FA ROTEX HPSU compact (V5) • 
10 x Technical data
10.1.2 ROTEX HPSU compact 508/516
Type ROTEX HPSU compact
508 DB 516 DB 508 BIV 516 BIV
Can be used with an external heat pump unit
RRLQ006CA
V3/RRL
Q008
CAV3
RRLQ011CA
(V3/W1)*/
RRLQ014CA
(V3/W1)*/
RRLQ016CA
(V3/W1)*
RRLQ006CA
V3
/RRLQ008
CAV3
RRLQ011CA
(V3/W1)*/
RRLQ014CA
(V3/W1)*/
RRLQ016CA
(V3/W1)*
Dimensions and weights Unit
Dimensions (H x W x D) cm 180 x 79 x 79
Empty weight kg 111 116 113 118
Main components
Water heat circula-
tion pump
Type Grundfos UPM3K 25-75 CHBL RT
Speed rates Continuously variable (PWM)
Voltage V 230
Frequency Hz 50
Protection type IP 42
Maximum rated output W 45
Heat exchanger
(water/coolant)
Type Stainless steel underfloor heat exchanger
Heat insulation
EPP
Storage tank
Total storage capacity litres 477
Maximum permissible storag
e water temperature °C 85
Heat consumption at stand-b
y and at 60 °C kWh/24h 1.4
Domestic water heat
exchanger (stainless
steel 1.4404)
Water capacity heat exchanger litres 29
Maximum operating pressure bar 6
Domestic water heat exchanger sur-
face
m
2
6.0
Storage tank charg-
ing heat exchanger
(
stainless steel
1.4404)
Water capacity heat exchanger litres 12.1 17.4 12.1 17.4
Heat exchanger surface area m
2
2.5 3.5 2.5 3.5
Pressurised solar
heat exchan
ger
(stainless steel
1.4404)
Water capacity heat exchanger litres 12.5
Heat exchanger surface area m
2
—1.7
Thermal perfor-
mance data
1)
Hot water quantity without re-heating
at a flow rate of 8 l/min (12 l/min)
(T
S
=50 °C)
litres
364 (318)
328
4)
(276
4)
)
324 (282)
2
88
4)
(240
4)
)
Hot water quantity without re-heating
at a fl
ow rate of 8 l/min (T
S
=60 °C)
litres 540 (494) 492 (444)
Hot water quantity without re-heating
at a fl
ow rate of 8 l/min (12 l/min)
(T
S
=65 °C)
litres 612 (564) 560 (516)
Re-heating rime with a draw-off quan-
tity of:
min.140 l = 5820 Wh (Ø bathtub) 45 25 45 25
90 l = 3660 Wh (Ø shower draw-off
qu
antity)
30 17 30 17
Pipe connections
Cold and hot water inches 1" AG
Heating flow and return flow inches 1" IG
Solar connections
inches 1" IG
inches 3/4" IG + 1" AG

Table of Contents

Other manuals for Rotex HPSU compact (V5)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotex HPSU compact (V5) and is the answer not in the manual?

Rotex HPSU compact (V5) Specifications

General IconGeneral
BrandRotex
ModelHPSU compact (V5)
CategoryHeat Pump
LanguageEnglish

Related product manuals