2 x Safety
2.4.6 Requirements for the heating water
Observe the current technological regulations to
prevent corrosion products and deposits.
Minimum requirements regarding the quality
of filling and supplementary water:
– Water hardness (calcium and magnesium,
calculated as calcium carbonate):
3 mmol/l
– Conductivity: 1500 (ideal 100) ȝS/cm
– Chloride: 250 mg/l
– Sulphate: 250 mg/l
– pH value (heating water): 6,5 - 8,5
Using filling water and top-up water which does
not meet the stated quality requirements can
cause a considerably reduced service life of the
equipment. The responsibility for this is entirely
that of the operator.
2.4.7 Operation
The ROTEX HPSU compact:
Ɣ Do not operate until all installation and
connection work is completed.
Ɣ Only operate with a completely full storage
tank (Level indicator) and heating circuit.
Ɣ Operate at a maximum pressure of 3 bar.
Ɣ Only connect with a pressure reducer on the
external water supply (supply line).
Ɣ Only operate the with the specified quantity of
refrigerant and the type of refrigerant
specified.
Ɣ Only operate if the protective cover is
installed.
The prescribed maintenance intervals must
be maintained and the inspection work must
be carried out.
2.4.8 Instructing the user/owner
Ɣ Before you hand over the ROTEX HPSU
compact, explain to the user/owner how to
operate and check the system.
Ɣ Hand over the technical documentation (this
document and all supporting documents) to
the user and advise him that these documents
must be made available at all times and be
stored in the immediate vicinity of the unit.
Ɣ Make a record of the handover by filling out
and signing the installation and instruction
forms jointly with the user/owner.