Regreasing intervals
The necessary relubrication intervals depend essentially on the level of dirt in the environment
and on the ON time of the motor. For this reason, they can only be defined taking into account
the respective operating conditions. Make sure that the groove in the seal is full of grease at
all times.
9.1.10 Keeping the cooling air flow clean
The cooling ducts must be free of any pollution in order that the machine is adequately cooled.
Regularly clean the grids, ducts, ribs, pipes etc. to remove dust and pollution.
9.1.11 Touch up any damaged paintwork
If the paint is damaged, it must be repaired in order to protect the unit against corrosion.
Note
Paint system
Contact the Service Center (Page 137) before you repair any paint damage. They will provide
you with more information about the correct paint system and methods of repairing paint
damage.
9.1.12 Maintaining terminal boxes
Requirement
The machine is de-energized.
Checking the terminal box
Terminal boxes must be regularly checked for tightness, undamaged insulation, and tight
terminal connections.
If dust or humidity have infiltrated the terminal box, this should be cleaned and dried
(particularly the insulators).
Check all the seals and sealing surfaces and address the cause of the leakiness.
Maintenance
9.1 Inspection and maintenance
SIMOTICS TN Series N-compact 1LA8
Operating Instructions 05/2016 105

Table of Contents

Other manuals for Siemens 1LA8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1LA8 and is the answer not in the manual?

Siemens 1LA8 Specifications

General IconGeneral
BrandSiemens
Model1LA8
CategoryEngine
LanguageEnglish

Related product manuals