Page #139 background image
Technical data
B
B.1 Tightening torques for screw and bolt connections
Bolt locking devices
Refit nuts or bolts that are mounted together with locking, resilient, and/or force-distributing
elements with identical, fully-functional elements when re-assembling. Always renew keyed
elements.
When screwing together threads secured with a liquid adhesive, use a suitable medium
such as Loctite 243.
Always use suitable securing devices or removable adhesives (e.g., Loctite 243) when
installing fixing bolts with a clamping length of less than 25 mm. The clamping length is
taken as the distance between the head of the bolt and the point at which the bolt is screwed
in.
Tightening torques
The bolted connections with metal contact surfaces, such as end shields, bearing cartridge
parts, terminal box parts bolted onto the stator frame, should be tightened to the following
torques, depending on the thread size:
Table B-1 Tightening torques for bolted connections with a tolerance of ±10%.
Case M4 M5 M6 M8 M10 M12 M16 M20 M24 M30 M36 M42 M48 M56
A 1.2 2.5 4 8 13 20 40 52 80 150 - - - - Nm
B 1.3 2.6 4.5 11 22 38 92 180 310 620 1080 1700 2600 4200 Nm
C 3 5 8 20 40 70 170 340 600 1200 2000 3100 4700 7500 Nm
SIMOTICS TN Series N-compact 1LA8
Operating Instructions 05/2016 139

Table of Contents

Other manuals for Siemens 1LA8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1LA8 and is the answer not in the manual?

Siemens 1LA8 Specifications

General IconGeneral
BrandSiemens
Model1LA8
CategoryEngine
LanguageEnglish

Related product manuals