Configuring Communication Connections
110
SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06
4.5 Configuring ISO-on-TCP Connections Properties
Introduction
As well as the entry the connection table, you can also modify specific connection
parameters that were entered as defaults during the New connection dialog.
Opening the Dialog
To call the dialog for special connection properties, follow the steps outlined below:
1. Select the required connection in the connection table.
2. Select the menu option Edit
"
Object Properties
Result: The “Properties ISO-on-TCP Connection” dialog appears.
Tabs
The following tabs are available for ISO-on-TCP connections:
S General
Displays the parameters of the connection and the local name of the
ISO-on-TCP connection.
S Addresses
Displays the local and remote address information.
S Options
Here, you can decide whether or not you want to use the connection for one of
the access types FETCH or WRITE.
S Overview
This is an overview of all the configured ISO-on-TCP connections of the
selected S7 station with their parameters and the status of the connection.
S Status Information
This tab displays the current status information for the connection (valid at the
time the dialog is opened). This information corresponds to that displayed by
NCM diagnostics.