EasyManuals Logo

Siemens NCM S7 User Manual

Siemens NCM S7
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
Configuring Communication Connections
119
SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06
4.6 Configuring TCP Connection Properties
Introduction
After the entry in the connection table, you can modify specific connection
parameters for each configured connection that were given default values when
you created the connection.
Opening the Dialog
To call the dialog for special connection properties, follow the steps outlined below:
1. Select the required connection in the connection table.
2. Select the menu option Edit
"
Object Properties
Result: The “Properties – TCP Connection” dialog appears.
Tabs
The following tabs are available for TCP connections:
S General
Displays the parameters of the connection and the local name of the TCP
connection.
S Addresses
Displays the local and remote address information.
S Options
Here, you can decide whether or not you want to use the connection for one of
the access types FETCH or WRITE.
S Overview
This is an overview of all the configured TCP connections of the selected S7
station with their parameters and the status of the connection.
S Status Information
This tab displays the current status information for the connection (valid at the
time the dialog is opened). This information corresponds to that displayed by
NCM diagnostics.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens NCM S7 and is the answer not in the manual?

Siemens NCM S7 Specifications

General IconGeneral
BrandSiemens
ModelNCM S7
CategorySwitch
LanguageEnglish

Related product manuals