Configuring Communication Connections
128
SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06
4.7 Configuring UDP Connection Properties
Introduction
After the entry in the connection table, you can modify specific connection
parameters for each configured connection that were given default values when
you created the connection.
Opening the Dialog
To call the dialog for special connection properties, follow the steps outlined below:
1. Select the required connection in the connection table.
2. Select the menu option Edit
"
Object Properties
Result The “Properties – UDP Connections“ dialog appears.
Tabs
The following tabs are available for UDP connections:
S General
Displays the parameters of the connection and the local name of the UDP
connection.
S Addresses
Displays the local and remote address information.
S Overview
Overview of all configured UDP connections of the selected S7 station with
corresponding parameters and the status of the connection.
S Status Information
This tab displays the current status information for the connection (valid at the
time the dialog is opened). This information corresponds to that displayed by
NCM diagnostics.