Technical information
8.4 Technical specifications
SIMATIC IPC477E
136 Operating Instructions, 12/2016, A5E37455003-AB
8.4.4
AC voltage supply
Input voltage 100-240 VAC (-15 % / +20 %); 50-60 Hz
Output power of the power supply
Max. 80 W
Power failure buffering "AC FAIL" becomes active after >= 20 ms,
The power supply continues to buffer for >= 20 ms at
>= 93 V
Efficiency
>85 %
Note
Inrush current
The power consumption of the device is dependent
on the device configuration and can be
up to 1.1
A.
The peak value of the starting current depends on the input voltage and the impedance of
the power supply, and can be up to 50
A for < 1 ms. This will not have a negative impact on
device functionality.