Technical information
8.8 Functional scope in Windows
SIMATIC IPC477E
160 Operating Instructions, 12/2016, A5E37455003-AB
When establishing a connection to the AMT PC, the KVM viewer may prompt the user to
enter a six-figure code. This code is displayed on the screen of the AMT PC. The user of the
AMT PC must inform the user of the KVM viewer of this code.
This code query needs to be set up on the KVM viewer.
1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx.
2. Select the value "KVM" for "User Consent".
To allow a user with administrator privileges to avoid this code query, follow these steps:
1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx.
2. Enable "Opt-in configurable from remote IT".
Functional scope in Windows
8.8.1
Windows Embedded Standard 7
The overview shows the most important device functions under
Windows Embedded Standard 7:
Accessories Available Available
DirectX and Windows Device Experience
Encrypted File System (EFS)
File Based Write Filter (FBWF)
Hibernate Once Resume Many (HORM)