Maintaining and servicing your device
7.4 Installing and removing hardware
SIMATIC IPC477E
Operating Instructions, 12/2016, A5E37455003-AB
91
7.4
Installing and removing hardware
7.4.1
Built-in unit
7.4.1.1
Replacing back-up battery (devices with 15", 19" or 22" display)
Requirements
The device is disconnected from the power supply.
The device is open, see the section "Opening the device (Page 79)".
Replacement battery
Procedure
Removal
NOTICE
Time setting is lost
The time and the setup settings are deleted if it takes longer than 30
seconds to replace the
battery. The device time may no longer be synchronized. Time-controlled programs will no
longer run or will run at the wrong time. This may damage the plant.
Set the device time again.
Note
Writing down the BIOS settings
Make a
note of the current BIOS setup settings or save them as a user profile in the BIOS
setup Exit menu. You will find a list for noting the settings in the BIOS description.

Table of Contents

Other manuals for Siemens SIMATIC IPC477E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC477E and is the answer not in the manual?

Siemens SIMATIC IPC477E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC477E
CategoryIndustrial PC
LanguageEnglish

Related product manuals