ELECTRICAL SYSTEM 6-31
RECHARGING OPERATION
Using the multi circuit tester, check the battery voltage. If the
voltage reading is less than the 12.0 V (DC), recharge the
battery with a battery charger.
&
When recharging the battery, remove the battery from
the motorcycle.
NOTE:
Do not remove the caps on the battery top while recharging.
Recharging time: 3 A for one hour or 0.7 A for 5 to 10 hours
&
Be careful not to permit the charging current to exceed
5 A at any time.
After recharging, wait for more than 30 minutes and check the
battery voltage with a multi circuit tester.
If the battery voltage is less than the 12.5 V, recharge the bat-
tery again.
If battery voltage is still less than 12.5 V, after recharging, re-
place the battery with a new one.
When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.