Adaptive effects and hearing the effect as the algorithm
re-assesses your voice input.
The ADAPTIVE Check Boxes
These show whether the automatically-adjust-
ing Adaptive feature is enabled for the SHAPE or
COMPRESS controls.
NOTE: If either or both ADAPTIVE check boxes is
unchecked, the associated control is set to MANUAL.
Manual adjustment is possible by using the Navigate
buttons to go to the edit tab associated with it and
changing the controls on that tab.
The SHAPE Control
“Shape” is the name given to the automatically adjusting
EQ that is activated by the ADAPTIVE check box. When
the Adaptive feature is activated, Shape processing offers
an EQ curve that adds an airy brightness, or “sizzle” to
your voice while reducing “mud” due to the proximity
effect from singing closely into a cardioid microphone.
Adjusting the control from 0% to 50% reduces mud
while increasing brightness to a useful range for your
voice. Turning from 50% up to 100% adds more
brightness.
Reducing Mud
For singers who have a voice with less bass frequencies,
the “mud” reduction may be less and perhaps not
noticeable at all. This is a good thing - your voice is nicely
balanced regarding bass frequencies. For the average
male singer or women who sing closely on their mic, the
reduction in bass will be noticeable and beneficial. When
voices have too much bass, they tend to become lost
in the other instruments that occupy those frequencies
resulting in sonic clutter. Reducing bass has the natural
effect of emphasizing mid and upper frequencies which
allow the voice to cut through dense instrumentation.
Lastly, the term “proximity effect” and “cardioid” need
to be clarified as they can cause bass build up. The typical
microphone used by singers has a pickup pattern called
“cardioid” or heart-like, because it picks up less sound at
the rear than at the front. This intends to reduce other
instruments or sounds from getting into the front of the
The Global Controls: Tone
39

Table of Contents

Other manuals for TC-Helicon Voicelive 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TC-Helicon Voicelive 2 and is the answer not in the manual?

TC-Helicon Voicelive 2 Specifications

Operating Environment IconOperating Environment
operating temperature32° F to 122° F (0° C to 50° C)
storage temperature-22° F to 167° F (-30° C to 70° C)
humidityMax. 90 % non-condensing
Power IconPower
external power supply mains voltage100 to 240 VAC, 50 to 60 Hz
power consumption<14 W
Analog Inputs IconAnalog Inputs
mic input impedance2.14/1.07 kOhm
line input impedance13/6.5 kOhm
guitar input impedance1 MOhm
Analog Outputs IconAnalog Outputs
output impedance100/50 Ohm
output range16 dBu / 0dBu
dynamic range> 109 dB, 20 Hz to 20 kHz
Weight and Dimensions IconWeight and Dimensions
dimensions13.8" x 3" x 8.5" (350 x 76 x 216)
weight5 lb. (2.3 kg)