Field or control Description
Identifier High Sets the frame identifier high pattern which, if exceeded, will cause a trigger.
A
vailable when Trigger On = Identifier and Trigger When Data is set to Inside Range or Outside
Range.
Identifier Low Sets the frame identifier low pattern which, if exceeded, will cause a trigger.
Available when Trigger On = Identifier and Trigger When Data is set to Inside Range or Outside
Range.
Cycle Count Sets the cycle count pattern on which to trigger. Use in conjunction with the Trigger When field to
specify the exact trigger condition.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Cycle Count or Header Fields and Trigger When Data is not set to
Inside Range or Outside Range.
Cycle Count High Sets the cycle count high limit which, if exceeded, will cause a trigger.
Available when Trigger On = Cycle Count and Trigger When Data is set to Inside Range or Outside
Range.
Cycle Count Low Sets the cycle count low limit which, if exceeded, will cause a trigger.
Available when Trigger On = Cycle Count and Trigger When Data is set to Inside Range or Outside
Range.
Indicator Bits Sets the indicator bits on which to trigger.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields .
Payload Length Select the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values.
Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields.
Header CRC Select the Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields.
Trigger When Data Sets the trigger when data condition.
When set to Inside Range or Outside Range, fields are displayed to set a high and low boundary
pattern for the specified trigger type.
Available when Trigger On = Identifier or Identifier & Data.
Data Bytes Sets the number of data bytes on which to trigger (one to sixteen bytes). Use the A knob to change the
value. Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Data or Identifier & Data.
Table continued…
Menus and dialog boxes
3 Series Mixed Domain Oscilloscope Printable Help 205

Table of Contents

Other manuals for Tektronix MDO34

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO34 and is the answer not in the manual?

Tektronix MDO34 Specifications

General IconGeneral
BrandTektronix
ModelMDO34
CategoryTest Equipment
LanguageEnglish

Related product manuals