RF badge menu
Use the RF badge menu to set spectrum parameters including reference level, amplifier mode, spectrum traces, detection method, and
spectrogram.
T
o open the RF badge menu, double-tap the badge.
RF badge menu, fields and controls
Field or control Description
Display Enables (On) or disables (Off) showing RF traces.
Reference Level Sets the reference level using the multipurpose knob, double-tap to bring up the virtual keypad, or tap
the up and down arrows to change the level
Scale Sets the vertical scale using the multipurpose knob, double-tap to bring up the virtual keypad, or tap
the up and down arrows to change the scale.
Position
Set the vertical position using the virtual keypad.
Label
Enter a label using the keyboard.
Units Sets the measurement unit to use in the vertical scale in the RF waveform view.
Amplifier Mode When a TPA-N-PRE (preamplifier) is attached to the RF input, tap to toggle between Auto and Bypass
mode. The readout indicates preamplifier mode.
Spectrum Traces
Add or remove Normal, Average, Max Hold, or Min Hold traces to the display.
• Normal sets the spectrum trace to show the first sample point data in each sample interval.
• A
verage sets the spectrum trace to show the average of the normal points in each sample interval
over several acquisitions.
• Max Hold sets the spectrum trace to show the highest amplitude points in each sample interval
over several acquisitions.
• Min Hold sets the spectrum trace to show the lowest amplitude points in each sample interval over
several acquisitions.
Sets the trace mode to show all available sample point data in the spectrum trace.
Detection Type
Displays the detection type, or, if the detection method is set to Manual, allows you to select the
detection type: +Peak, Average, Sample, or -Peak.
Detection Method
Select the detection method:
• Auto allows the instrument to select the detection type.
• Manual allows you to select the detection type: +Peak, Average, Sample, or -Peak.
Number of Averages When the Average spectrum trace is selected, sets the spectrum trace to show the average of the
normal points in each sample interval over several acquisitions.
Table continued…
Menus and dialog boxes
3 Series Mixed Domain Oscilloscope Printable Help 233

Table of Contents

Other manuals for Tektronix MDO34

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO34 and is the answer not in the manual?

Tektronix MDO34 Specifications

General IconGeneral
BrandTektronix
ModelMDO34
CategoryTest Equipment
LanguageEnglish

Related product manuals