Type:
Setting or query
Setting syntax:
LRI ON
LRI OFF
Examples:
LRI ON
LRI OFF
Query syntax:
LRI?
Query response:
LRI ON;
LRI OFF;
Discussion:
This command enables the logic supply regulation inter-
rupt. SRQ is asserted when the logic supply changes be-
tween any two of the three regulated modes. These modes
are constant voltage, constant current and unregulated. The
device dependent serial poll status byte indicates which
supply caused the SRQ and the mode changed to. See Ta-
ble
3-1.
The status message returned (with RQS asserted), as a
result of enabling the LRI interrupt, does not necessarily
show the instruments present status. It shows the status
which was latched at the time the interrupt occurred. Use
the command REG? to determine present status.
LSOUTPUT
Type:
Setting or query
Setting syntax:
LSOUT ON
LSOUT OFF
Examples:
LSOUT ON
LSOUT OFF
Query syntax:
LSOUT?
Query response:
LSOUT ON;
GOUT OFF;
Discussion:
This command connects or disconnects the logic supply
to its positive output terminal. Some protective components
remain connected to the output terminals. Refer to sche-
matic
8
for components that remain connected.
LSOUTPUT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix PS 5010 and is the answer not in the manual?

Tektronix PS 5010 Specifications

General IconGeneral
BrandTektronix
ModelPS 5010
CategoryPower Supply
LanguageEnglish

Related product manuals