VLOGIC
Type:
Setting or query
Setting syntax:
VLOG <number>
VLOGIC <number>
Examples:
VLOG 5
VLOGIC
4.97
Query syntax:
VLOG?
VLOGIC?
Query response example:
VLOGIC 5.1
;
Discussion:
This command sets the logic supply voltage limit to the
value specified. The units are volts for both the setting and
query versions. The range
is
4.5
V
to 5.5 V and the resolu-
tion is 0.01 0 V.
REV
OCT
1986
VLOGIC
VNEGATIVE
Type:
Setting or query
Setting syntax:
VNEG 26.7
VNEGATIVE -3.5
Query syntax:
VNEG?
VNEGATIVE?
Query response example:
VNEG 23.2;
VNEG 1
.O;
Discussion:
This command sets the negative floating supply voltage
limit to the value specified. The units are volts for both the
setting and query versions. The range is 0 to -32 V and the
resolution is 0.01
0
V
to 10 V and 0.1 0 V above 10.0
V.