12
EPG-SPRINT XE
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2354913
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION IN ACCORDANCE WITH ATEX
3.2 PERMISSIBLE DEVICE COMBINATIONS
The following powder spray guns may be connected to the EPG-SPRINT XE:
Manual spray guns
– Corona spray gun PEM-X1, PEM-X1 CG, PEM-C3, PEM-C4,
PEM-C4-Ergo
– Tribo spray gun PEM-T3
Automatic spray guns
– Corona spray gun PEA-C3, PEA-C4
– Corona spray gun PEA-C3XL, PEA-C4XL
– Tribo spray gun PEA-T3
– Tribo spray gun PEA-T3XL
Older or other gun types may only be connected to the control unit after rst checking
their suitability with WAGNER.
Permissible device combinations for the USA and Canada, see Chapter 14.5 "FM Approval".
The device is suited for use in potentially explosive areas, in accordance with Test Certicate
PTB 12 ATEX 5001.
0102 II 3(2)D
CE: European Communities
0102: Number of notied body which issues the recognition of quality assurance in
production.
Ex: Symbol for explosion protection
II: Device class II
3: Category 3 (Zone 22)
(2): Impact on equipment of category 2
D: Ex-atmosphere dust
IP64: Protection class 64
80 °C Temperature class: maximum surface temperature < 80 °C; 176 °F