6.6.1 GROUNDING THE POWDER COATING SYSTEM
1 Only use mains cables with grounding strand!
2 Connect grounding cable with booth and signal ground!
3 Connect grounding cable to an uncoated metal part of the booth!
4 Remove all paint from hooks and other hanger parts!
5 Do not wear non-conducting gloves!
6 Wear electrostatically conductive footwear!
7 The oor must be electrostatically conductive!
Sparks between conveyor, conveyor hooks (hangers) and work piece can occur
if electric contact points between conveyor, conveyor hooks (hangers) and work
piece are not suciently cleaned and therefore the work pieces are not suciently
grounded!
These sparks can cause heavy radio frequency interference (EMC).