4.2.5 HANDLING POWDER LACQUERS
4.2.4 CLEANING
When preparing or processing the powder and cleaning the device, take note of the
processing regulations laid down by the manufacturer of the powder lacquers being
used.
Take note of the manufacturers instructions and the relevant environmental protection
regulations when disposing of powder lacquers.
Implement the prescribed safety measures, in particular the wearing of safety glasses
and safety clothing as well as the use of protective hand cream.
Use a mask or breathing apparatus if necessary.
To ensure sucient protection of health and the environment, only operate the device
in a powder booth or on a spray wall with activated ventilation (exhaust air).
Before starting cleaning or any other manual work, the high voltage in the spray area
must be shut down and locked to prevent it from being switched back on.
Lock the compressed air supply and decompress the device.
Secure the device against being switched back on without authorization.
Use only electrically conducting and grounded tanks for cleaning uids.
Preference should be given to non-ammable cleaning uids.
Flammable cleaning liquids may only be used if, after switching o the high voltage, all
high-voltage conducting parts are discharged to a discharge energy of less than 0.24
mJ before they can be accessed.
Most ammable solvents have an ignition energy of around 0.24 mJ or 60 nC.
The cleaning agent's ash point must be at least 15 K above the ambient temperature.
Only mobile industrial vacuum cleaners of design 1 (see EN 60335-2) may be used to
remove dust deposits.
4.3 PROTECTIVE AND MONITORING EQUIPMENT
Protective and monitoring equipment must not be removed, modied or rendered
unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment, the system must not
be operated until these defects are remedied.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-SPRINT XE and is the answer not in the manual?

WAGNER EPG-SPRINT XE Specifications

General IconGeneral
BrandWAGNER
ModelEPG-SPRINT XE
CategoryPaint Sprayer
LanguageEnglish

Related product manuals