7.8.4 PROCEDURE FOR CLEANING FLUSHING WITH AUTOMATIC GUNS
Procedure:
1. End coating operation.
2. Remove powder suction unit (suction lance, powder injector) from powder tank.
3. Switch on ush function by pressing "Flush" button 17 on the control unit.
LED display 18 starts to ash and indicates readiness for ushing.
4. Process should be repeated for each spray gun that is to be ushed.
If you do not want a ushing process, press "Standby" button 15.
5. Start ush process using "Gun Start" on controller.
6. Stop ush process using "Gun Stop" on controller.
7. Re-activate control units in standby mode by pressing the "Standby" button 15.
8. Press "Flush" button 17 to return to normal coating mode.
The LED display 18 no longer ashes.
9. Once the suction lance has been lowered into the powder tank, the coating operation
can be continued again.
Note:
If conguration parameter C16 is set to "ON", the ush function can only be activated via