4 Information on Unit BlueCool S Series
8
4.7 Technical Data
Model S8-R-230V-
REV-R410a
S10-R-230V-
REV-R410a
S13-R-230V-
REV-R410a
S16-R-230V-
REV-R410a
S20-R-230V-
REV-R410a
S27-R-230V-
REV-R410a
Cooling capacity [BTU/
h] *1
8,000 10,000 13,000 16,000 20,000 27,000
Cooling capacity [kW]
*1
2.4 2.9 3.8 4.7 5.9 7.9
Rated voltage [V] 230
Frequency [Hz] 50
Current draw (run-
ning) [A] *2
2.4 - 3.5 2.6 - 4.0 3.6 - 6.3 4.9 - 7.2 5.9 - 8.9 7.0 - 10.5
Current draw (start)
[A] *3
9.7 10.3 14.3 21.8 21.8 46.5
Current draw - effec-
tive value RMS40 [A]
*4
20 20 27.3 38.7 45.6 63.3
Current draw with
blocked rotor LRA [A]
18.7 18.7 24 37 43 62
Recommended sup-
ply line circuit breaker
[A]
16 16 16 16 16 20 (compressor
only)
Air flow
[m
3
/h] *5
275 400 500 625 625 2x 550
Air flow
[162 cfm/h] *5
162 235 294 368 368 2x 324
ø Sea water connec-
tion
[mm] - [inches]
19 - 3/4”
Minimum sea-water
flow rate
[l/min]
8 1012141721
Recommended sea
water pump *6
WB350 WB350 WB350
WB500G
WB500
WB500G
WB500
WB500G
WB1000
WB1000G
max. permissible am-
bient temperature [°C]
+40
Net weight per unit
[kg]
20 22 27 31 34 46
Dimensions
(LxDxH) [mm]
Also see Fig. 5.
313x400x301 310x475x310 355x500x320 360x540x330 340x590x370 510x570x390
Dimensions
(LxDxH) [inches]
Also see Fig. 5.
12.3x15.7x11.9 12.2x18.7x12.2 14.0x19.8x12.6 14.2x21.3x13.0 13.4x21.3x14.6 20.1x22.4x15.4
Minimum distance
(recommended dis-
tance), on right.
Also see Fig. 5.
50 (100) 40 (100)
Minimum distance
(recommended dis-
tance), on left.
Also see Fig. 5.
40 (100) 50 (100)