11 Inspection and Maintenance BlueCool S Series
42
11.4 Checklist for inspection and maintenance
Table 6 Checklist for inspection and maintenance
Date
1 Check the air filter on the evaporator and clean if necessary.
See Chapter 11.1 and Fig. 4, No. 8.
2 Check the flow rate of the sea water circuit at the sea water
outlet.
See Chapter 11.2 and Fig. 8, No. 6.
3 Check and clean the sea water strainer. Observe the
specifications of the filter manufacturer for this purpose.
See Chapter 11.2 and Fig. 8, No. 2.
4 Check the entire sea water circuit for leaks.
See Chapter 11.2 and Fig. 8.
5 Check the condensed-water drainage from the condensate
tray and condensed-water drain line for clear passage and
leaks.
See Chapter 11.2.
6 Clean the sea water circuit.
See Chapter 11.2.
7 Check the electrical connections for corrosion to the
contacts and firm seating.
See Chapter 11.3 and Fig. 22.
8 Check the shaft seal of the pump and replace it if necessary
(does not apply to magnetically coupled pumps).