21
0A192000
0B256000
0C288000
0D384000
0E512000
0F576000
10768000
n.x□xx
Stop bit
2
02 bits, 21 bit
At once
n.□xxx
Parity bit
2
02
0:no parity, 1: odd parity, 2: even parity
At once
Note: data bit cannot be changed, it is 8 bits.
RS-485 port
Pin no.
Name
CN1-14
A
CN1-15
B
Communication parameters:
RS485 default communication parameters: baud rate 19200bps, data bit 8, stop bit 1, even parity,
Modbus station no.1.
The Modbus station no. can be set through P7-00:
Parameter
Function
Default value
Range
Effective time
P7-00
Modbus station no.
1
0255
At once
The communication parameters can be set through P7-01:
Parameter
Function
Default value
Range
Effective
time
n.xx□□
Baud rate
06
0010
00300
01600
021200
032400
044800
059600
0619200
0738400
0857600
09115200
0A192000
0B256000
0C288000
0D384000
0E512000
0F576000
10768000
111M
122M
133M
144M
155M
At once
910
15 14 13
12
11
1
2
345
6
7
8

Table of Contents

Other manuals for Xinje DS3E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3E Series and is the answer not in the manual?

Xinje DS3E Series Specifications

General IconGeneral
BrandXinje
ModelDS3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals