0:no parity, 1: odd parity, 2: even
parity
Note: data bit cannot be changed, it is 8 bits.
P7-02 RS485 communication protocol setting:
RS485
communication
protocol
2: Xnet filedbus protocol
1. Support standard Modbus RTU protocol, it is used as Modbus slave device.
2. RS232 port and RS485 port can be used at the same time.
3-1-2.Signal terminals
3-1-2-1. Pulse signal
CW, CCW double pulse
mode
Collector open circuit (24V) input positive signal: P+24V/D+24V
Differential mode (5V) input positive signal: P+5V/D+5V
The interface circuit of Pulse + direction and CW, CCW mode:
PLC, SCM, etc servo drive
Note:
(1) P-/P+24V, D-/D+24V power supply range is 18~25V. if the voltage
is lower than 18V, the pulse and direction will be error.
(2) To avoid the interference, please use shielded twisted-pair cable.
When upper
device is open
collector output,
please use this
wiring diagram.
Please note:
P+5V and
D+5V must be
vacant.