DS3L-2□P□-PFA
DS3L-4□P□-PFA
PLC, SCM, etc servo drive
Note: Please use tisted shielded pair to avoid interference
(1) Servo drive pulse input will be ON at 10mA.
(2) If the controller is XINJE PLC, pulse output terminal rated current 50mA, 1 channel pulse can
connect 5 servo drives. We suggest it cannot over 3 servo drives.
3-2-2-2.SI input signal
Please use relay or open collector transistor to connect. When using relay, please choose micro-current
relay. Otherwise, the contact will be not good.
Open collector (24V power supply)
Note: the max allowable voltage and current of open collector output circuit:
Voltage: max DC30V
Current: max DC50mA
3-2-2-3. SO output signal
Multi-functional output terminal
Note: please use twisted shielded pair to avoid interference.
SI
+24V
+
COM2
Y2
0V
+24V
R=2.2KΩ
R=2.2KΩ
+24V
0V
Y2
COM2
+
+24V
SI
When upper
device is 5V
differential
output, please
use this wiring
diagram. Please
note: P+24V
and D+24V
must be vacant.