57
P5-47
Alarm output /ALM
5-2-6
5-2-1. Servo ON setting
When servo ON signal is ineffective, the servo motor cannot run.
Parameter
Signal
name
Setting
Meaning
Modify
Effective
P0-03
Enable
mode
0
Not enable
Servo OFF
At once
1 (default)
I/O enable /S-ON
2
Software enable (F1-05 or
communication)
3
Bus enable (the model support bus
movement)
Parameter
Signal
Setting
Explanation
Range
P5-20
/S-ON
n.0001
(default
value)
When SI1 is ON, servo motor
powers on and enables to run.
0001~0015
n.0010
Always effective, no need to
wiring.
/S-ON signal can be set to other input via parameter P5-20.
the input terminal assigned by function parameters cannot be duplicated. Please refer to chapter
5-12-1.
5-2-2. Switch the motor rotate direction
Change the motor rotate direction without changing the motor wiring. The standard forward rotate
direction is “CCW rotate” look at the load side.
“Reverse mode” will change the motor rotate direction.
Mode
Forward rotate
Reverse rotate
Standard setting:
CCW is forward
rotate
Reverse mode:
CW is forward
rotate
Set the rotate direction
Parameter
Setting
Explanation
P0-05
0 (default setting)
Standard setting (CCW is forward running)
1
Reverse mode (CW is forward running)
5-2-3. Stop mode
Set the stop mode when servo is OFF or alarm.
Parameter
Function
Setting value
Default value
P0-27
Servo OFF stop mode
0 or 2
0
P0-29
Alarm
0 or 2
0
CCW
CCW
CW
CW

Table of Contents

Other manuals for Xinje DS3E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3E Series and is the answer not in the manual?

Xinje DS3E Series Specifications

General IconGeneral
BrandXinje
ModelDS3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals