P0-25= power value, P0-26= resistor
value (see chapter 3-1-4)
Real-time check the bus voltage, please
take attention of this terminal
DS3-21P5-PTA, DS3-22P3-PTA
Power supply input of
main circuit
3 phases AC 200~240V, 50/60Hz
Note: if using single phase 220V, please
connect power supply to R and T,
otherwise it will affect power-off
retentive function.
DS3-41P5-PTA
3 phases AC 360~400V, 50/60Hz
Internal regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-24=0
External regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-24=1, P0-25=power value,
P0-26=resistor value (see chapter 3-1-4)
Connect to ground terminal of motor,
then connect to the ground
Power supply input of
main circuit
3 phases AC 360~400V, 50/60Hz
Note: the ground wire is on the cooling
fin, do not connect to P+ or P-, please
check it before power on.
Internal regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-24=0
External regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-24=1, P0-25=power value,
P0-26=resistor value (see chapter 3-1-4)