8. Select [OK] to end the wizard.
ð
Automation Builder license is activated and starts.
5.2.3 Set-up communication parameters in windows
To set-up the communication between the PC and the PLC, e.g., for downloading the compiled
program, you have to set-up the communication parameters.
The IP address of your PC must be in the same class as the IP address of the CPU.
The factory setting of the IP address of the CPU is 192.168.0.10.
The IP address of your PC should be 192.168.0.X. Avoid X = 10 in order to prevent an IP con-
flict with the CPU.
Subnet mask should be 255.255.255.0.
1. Open Windows Control Panel. Click “Network and Internet
è Network and Sharing Center”.
2. Click Change adapter settings.
If using existing network with several devices, please pay attention on
given network rules or contact your system administrator.
3. Right-click Local Area Connection (Ethernet) and select Properties.
Change the IP
address
Getting Started
Engineering software Automation Builder > Set-up communication parameters in windows
2021/06/293ADR010635, 2, en_US18