AI1 - REMOTE SETPOINT
DI1 - REMOTE SETPOINT ENABLE
(CONTACT INPUT INVERT [L265])
AI2 - ADDITIVE FEED FORWARD
AIO - PROCESS VARIABLE
DI0 - FORCE OUTPUT TRACKING
(CONTACT INPUT INVERT [L264])
AI3 - TRACKING INPUT
DO0 - PROCESS ALARM 1
DO1 - PROCESS ALARM 2
AO1 - RETRANSMITTED PV
AO0 - CONTROLLER OUT
(CONTACT OUTPUT INVERT [L288])
(CONTACT OUTPUT INVERT [L289])
(0-20 mA OUTPUT [L473])
ALARMS RELATED DATAPOINTS
CONTROL ALARM MODE (B335)
0 - HIGH/LOW
1 - NONE
2 - HIGH/NONE
3 - NONE/LOW
4 - HIGH/HI-HI
5 - LOW/LO-LO
6 - HI SP DEVIATION/LO SP
DEVIATION
ALARM LIMIT 1 (C103)
ALARM LIMIT 2 (C104)
ALARM DEAD BAND (C105)
OUTPUT RELATED DATAPOINTS
AO0 0-20 mA OUTPUT (L472)
MANUAL FALLBACK DISABLE (L120)
HARD MANUAL LIMIT (L122)
OUTPUT HIGH LIMIT (C109)
OUTPUT LOW LIMIT (C110)
OUTPUT SLEW RATE (C118)
CON0 CONTROL RELATED DATA-
POINTS (SEE SECTION 16, TUNING,
OR SECTION 17, EASY-TUNE, TO
TUNE PID DATAPOINTS)
PROPORTIONAL BAND (C106) (P)
RESET TIME (C107) (I)
RATE TIME (C108) (D)
MANUAL RESET (C111)
REVERSE SWITCH (L106)
AUTO ENABLE (L114)
CONTROLLER SPAN (C115) [100]
CONTROLLER LOWER RANGE
(C116) [0]
OUTPUT TRACKING RELATED
DATAPOINTS
ENABLE OUTPUT TRACKING (L119)
AI3 ENGINEERING SPAN (C259)
AI3 ENGINEERING ZERO (C279)
AI3 DIGITAL FILTER INDEX (B272)
AI3 0-5 V INPUT (L419)
AI3 SQUARE ROOT SIGNAL (L443)
ADDITIVE FEED FORWARD
RELATED DATAPOINTS
AI2 ENGINEERING SPAN (C258)
AI2 ENGINEERING ZERO (C278)
AI2 DIGITAL FILTER INDEX (B271)
AI2 0-5 V INPUT (L418)
AI2 SQUARE ROOT SIGNAL (L442)
SETPOINT RELATED DATAPOINTS
CONTROL ZONE (C114)
SETPOINT HIGH LIMIT (C125)
SETPOINT LOW LIMIT (C126)
SETPOINT SLEW RATE (C117)
SETPOINT TRACKING
RELATED DATAPOINTS
AFFECTED BY THE SETPOINT
RELATED DATAPOINTS
SP TRACK ENABLE (L118)
PROCESS VARIABLE
RELATED DATAPOINTS
AI0 ENGINEERING SPAN (C256)
AI0 ENGINEERING ZERO (C276)
AI0 DIGITAL FILTER INDEX (B269)
AI0 0-5 V INPUT (L416)
AI0 SQUARE ROOT SIGNAL (L440)
REMOTE SETPOINT RELATED
DATAPOINTS
AFFECTED BY THE SETPOINT
RELATED DATAPOINTS
REMOTE SETPOINT ENABLE (L115)
REMOTE SETPOINT BIAS (B1) (C112)
REMOTE SETPOINT RATIO (K1) (C113)
AI1 ENGINEERING SPAN (C257)
AI1 ENGINEERING ZERO (C277)
AI1 DIGITAL FILTER INDEX (B270)
AI1 0-5 V INPUT (L417)
AI1 SQUARE ROOT SIGNAL (L441)
MISCELLANEOUS DATAPOINTS
TAGNAME (A000) [CON-0]
ENGINEERING UNITS (A001)
[PERCENT]
REVERSE VALVE (L109) [C] [O]
NOTE; BRACKETS [XXXX] CONTAIN DATA SHOWN IN RECTANGLES ON
THE DISPLAY.
Figure 6-2. CS1 Single Loop CON0 Datapoints
53MC5000 Process Control Station
6-4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ControlIT 53MC5000 and is the answer not in the manual?

ABB ControlIT 53MC5000 Specifications

General IconGeneral
BrandABB
ModelControlIT 53MC5000
CategoryController
LanguageEnglish

Related product manuals