IntervalEquipmentMaintenance activity
First change when DTC
ii
reads:
• 6,000 hours
Second change when DTC
ii
reads:
• 24,000 hours
Following changes:
• Every 24,000 hours
Axis-3 gear oilChanging
First change when DTC
ii
reads:
• 6,000 hours
Second change when DTC
ii
reads:
• 24,000 hours
Following changes:
• Every 24,000 hours
Axis-6 gear oilChanging
40,000 hoursRobotOverhaul
36 months or battery low alert
iii
Battery pack, measurement
system of type RMU101 or
RMU102 (3-pole battery con-
tact)
Replacement
Battery low alert
iv
Battery pack, measurement
system with 2-pole battery
contact, e.g. DSQC633A
Replacement
Every 12,000 hoursBalancing device bearings
and piston rod
Lubrication
i
Replace when damage or cracks are detected or life limit is approaching as specified in section
Expected component life on page 103.
ii
DTC = Duty Time Counter. Shows the operational time of the robot.
iii
The battery low alert (38213 Battery charge low) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
iv
The battery low alert (38213 Battery charge low) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See Operating manual - IRC5 with
FlexPendant for instructions.
Activities and intervals, optional equipment
The table below specifies the required maintenance activities and intervals for
common optional equipment. The maintenance of other external equipment for the
robot is detailed in separate documentation.
IntervalEquipmentMaintenance activity
Every:Signal lampInspection
12 months
102 3HAC039838-001 Revision: C
© Copyright 2013 ABB. All rights reserved.
3 Maintenance
3.2.2 Maintenance schedule
Continued

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 760 and is the answer not in the manual?

ABB IRB 760 Specifications

General IconGeneral
BrandABB
ModelIRB 760
CategoryRobotics
LanguageEnglish

Related product manuals