252 Rockwell Automation Publication 750-IN001P-EN-P - April 2017
Chapter 5 I/O Wiring
Drive Device Ports
Connectors, embedded devices, and installed option modules such as I/O,
communication adapters, and DeviceLogixâ„¢ options, have unique port number
assignments. Connectors and embedded devices have fixed port numbers that
cannot be changed. Option modules are assigned a port number when
installed.
Figure 139 - Drive Device Ports
Port Device Description
00 Host drive Fixed port for the drive.
01 HIM Fixed port at HIM cradle connector.
Splitter cable connector provides Port 01 when HIM cradle connector is
unused.
02 DPI port Handheld or remote HIM connection.
Splitter cable connection.
03 Splitter cable Connects to DPI port 02.
Provides Port 02 and Port 03.
04…08 Option modules Available ports for option modules. See Option Module Installation
on
page 253 for port recommendations for each option module.
IMPORTANT: Ports 07 and 08 are available on PowerFlex 755 Frame 2
drives and larger only. PowerFlex 755 Frame 1 drives and 753 drives do not
support ports 07 and 08.
09 Auxiliary power supply
option module
Designated port for the auxiliary power supply when connected via cable.
(PowerFlex 755 Frame 1 and 753 drives only. See page 277.)
10 Inverter Fixed port for inverter (PowerFlex 755 Frame 8 drives and larger only).
11 Converter Fixed port for converter (PowerFlex 755 Frame 8 drives and larger only).
12 Reserved for future use.
13 EtherNet/IP Fixed port for embedded EtherNet/IP (PowerFlex 755 drives only).
14 DeviceLogix Fixed port for embedded DeviceLogix.
00
01
03
02
02
13
10, 11, 14
05
09
06
04
08
07