Rockwell Automation Publication 750-IN100B-EN-P - July 2017 103
Power Wiring Chapter 5
Figure 53 - Frames 10…12 Drives
Frame 10 drive shown. Layout is typical for Frames 10…12.
Item Name Description Item Name Description
1 AC Bus AC power supply 5 Control Bus 120/240V and 24V AC control power supply connections
2 DC Bus DC+, DC- 6 Power Bus U/T1, V/T2, W/T3 motor connections
3 Testpoints DC+, DC- and R/L1, S/L2, T/L3 voltage testpoint sockets 7 PE Grounding
Bar
Terminating point to chassis ground for incoming AC line and
motor shield.
PE ground bar clamps, kit number SK-RM-GRNDCLMP-nn, are
available.
4 Power Bus R/L1, S/L2, T/L3 AC line input power connections 8 Nameplate Power module and LCL filter module nameplate locations