Rockwell Automation Publication 750-IN100B-EN-P - July 2017 85
Mechanical and Electrical Installation Chapter 4
Place the Enclosures
If your PowerFlex 755T product consists of multiple enclosures, the enclosures
must be arranged as shown in the dimensional drawings starting on page 39
.
Rig Lifting Hardware
All lifting equipment and lifting components (hooks, bolts, lifts, slings, chains,
and so forth) must be properly sized and rated to safely lift and hold the weight
of the equipment. See Shipment Sections and Approximate Weights
on
page 20
.
Rig the lifting hardware according to the following diagram.
Figure 46 - Lifting Hardware Geometry
ATTENTION: Install the drive on a level surface (± 1 mm per meter [±
0.036 in. per 36 in.] of drive length in all directions). If necessary, use metal
shims to level the enclosures before joining them; attempting to level after
joining may twist or misalign the enclosures.
ATTENTION: To guard against possible personal injury and/or equipment
damage…
• Inspect all lifting hardware for proper attachment before lifting equipment.
• Do not allow any part of the equipment or lifting mechanism to make
contact with electrically charged conductors or components.
• Do not subject the equipment to high rates of acceleration or deceleration
while transporting to the mounting location or when lifting.
• Do not allow personnel or their limbs directly underneath the equipment
when it is being lifted and mounted.