Power Fail Recovery
The Power Fail Recovery feature allows the cycle status to be
saved in memory in the event of a power failure.
If the power failure lasted less than 5 seconds, the cycle will re-
sume without requiring the user to press the START (enter) key-
pad to restart.
If the power failure lasted longer than 5 seconds, the Power Fail
Reset option is turned on, and the duration of the power failure is
less than or equal to the time programmed in the Power Fail Re-
set option, the START (enter) keypad will flash until it is pressed
and the cycle will restart from the point it left off.
If the power failure lasted longer than 5 seconds and the Power
Fail Reset option is turned oFF, the START (enter) keypad will
flash one second on and one second off until it is pressed. The cy-
cle will restart from the point it left off when START (enter) is
pressed.
If the power failure lasted longer than 5 seconds, lasted longer
than the time programmed in the Power Fail Reset option, and the
Power Fail Reset option is turned on, the control will reset the
cycle and lose all vending entered for the cycle.
Power Fail Recovery
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
88 Part No. 204370ENR1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE SWNNX2SP115TW01 and is the answer not in the manual?

ALLIANCE SWNNX2SP115TW01 Specifications

General IconGeneral
BrandALLIANCE
ModelSWNNX2SP115TW01
CategoryWasher
LanguageEnglish

Related product manuals