E9 Error flashes
In service test, rotate icematic motor in
pouring direction. Check if there is 12V
at control card motor socket (KN4) pins
7 and 8.
Replace Icematic
E9:
Icematic
Motor
Error
Turn on the refrigerator
Operation is successful
Yes
NoYes
Is there 12V?
Replace control board
In service test, rotate icematic motor in
correcting direction. Check if there is
12V at control card motor socket (KN4)
pins 7 and 8.
NoYes
Is there 12V?
Replace Icematic Replace control board