Table 38: Delivery Schedule*
Open Close
W# Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
3
S M T W T F S
02 : 30 02 : 45 03 : 00 03 : 05 03: 15 03: 30
Yes No 1 2 3 4 1 2 3 4 5 6 7 8
00 : 00 01 : 00
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
Program at least
one day Yes.
Day(s) of the week, but not on holidays
Yes Select at
least one
index
Program at least
one area Yes.
* Monday and Wednesday, In between 2:45 AM and 3:00 AM. Out between 3:15 AM and 3:30 AM.
Another alternative for delivery schedules is to automatically bypass specific points using skeds.
Table 39: Monthly Auditor’s Schedule*
Open Close
W# Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
4 S M T W T F S 07 : 00 08 : 00 08 : 30 14 : 00 14: 30 17: 00
Yes No 1 2 3 4 1 2 3 4 5 6 7 8
All days must be
programmed No.
Only on holidays No Select at
least one
index
Program at least
one area Yes.
* Sunday, In between 8:00 AM and 8:30 AM. Out between 2:30 PM and 5:00 PM..
5.1.2 User Group Windows
In this section, you can create up to eight User
Group periods where the passcodes for the group
chosen is enabled. One user group can have
multiple windows assigned to it over a 24-hour
period. See the
U### User Group
prompt in
Section 3.1 Passcode/Token Worksheet to assign
individuals to a group.
When you assign a
U### User Group
to one of the
eight windows, all passcodes for the group are
enabled ONLY for the period between the Enable
Time and Disable Time for assigned
User Windows
#
.
If a user is not assigned to a
U### User Group
or
the number programmed for the user for
U###
User Group
is not assigned to a
User Windows #
,
the passcode for that user is enabled all the time.
0101
0101
0101
User Group Windows DO NOT affect the
users token/card access authority. To
enable/disable tokens, the Sked Function
Access Levels On/Off must be used.
User Windows #
Default: 1
Selection: 1 to 8
Enter the User Windows number you want to
program.
UW# User Group
Default: 1
Selection: Blank, 1 to 8
Enter the number programmed for the group of
users in the
U### User Group
prompt. This group
has its user passcodes enabled/disabled when this
window runs.
0101
0101
0101
A User Group can be assigned to more
than one window in a 24-hour period, but
the windows must not overlap or exceed
the midnight boundary.

Table of Contents

Other manuals for Bosch D7412G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D7412G and is the answer not in the manual?

Bosch D7412G Specifications

General IconGeneral
Partitions8
Power Supply16.5 VAC, 40 VA
User Codes99
Users99
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (32°F to +120°F)

Related product manuals