Figure 3: User Group 122 Example
Master User:
ID 122
.
CRD ID 122-0
Sub User -1: ID 122-1
CRD ID 122-1
Sub User -2: ID 122-2.
CRD ID 122-2
Sub User -3: ID 122-3.
CRD ID 122-3
2
1
1 - User passcode
2 - User token/card
0101
0101
0101
In reporting systems using modem format, all three digits of the User ID Code are transmitted to the
central station with appropriate reports. Central station automation computer systems may only accept
Zonex and COMEX style User Ids. See Point/User Flag in Section 2.1 Phone.
In BFSK, only one number is transmitted. This number represents a group of ten users as shown in Table 28. Users
100 through 249 do not report in BFSK format.
Table 28: BSFK User Code Report
User Code
000 to 009
User Code
010 to 019
User Code
020 to 029
User Code
030 to 039
User Code
040 to 049
User Code
050 to 059
User Code
060 to 069
User Code
070 to 079
User Code
080 to 089
User Code
090 to 099
BFSK
Report
0
BFSK
Report
1
BFSK
Report
2
BFSK
Report
3
BFSK
Report
4
BFSK
Report
5
BFSK
Report
6
BFSK
Report
7
BFSK
Report
8
BFSK
Report
9
User ###
Default: 001
Selection: 000 or 001 to 249 (001 to 099 for the
D7412G)
Enter the User number you are programming.
0101
0101
0101
User 000 is the Service Authority Level
(Level 15). You cannot change the
programming for user 000.
Only the Service Authority Level (User
000) can delete User 000. When a user
other than User 000 tries to delete the
passcode for User 000, the command
center displays NOT IN USE.
User 000 cannot be added/changed at
the command center whether it exists or
not.
U### Passcode
Default: See
Program Record Sheet
Selection: Three to six digits ( 0 to 9)
Enter three to six digits to enable a passcode for the
master user in this group.
0101
0101
0101
User I.D.000 is the Service Passcode. The
default Service Passcode is 123.
The programmer does not allow you to
enter any passcode number that could
conflict with a duress passcode. If Duress
Type is a 1, passcodes within a range of 1
for existing passcodes cannot be entered.
This rule applies even if duress is disabled.
For example, once a passcode of 654321
is entered, 654322, 654323, 654320,
and 654329 cannot be entered.

Table of Contents

Other manuals for Bosch D7412G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D7412G and is the answer not in the manual?

Bosch D7412G Specifications

General IconGeneral
Partitions8
Power Supply16.5 VAC, 40 VA
User Codes99
Users99
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (32°F to +120°F)