D9412G/D7412G | Program Entry Guide | 5.0 RADXSKED EN | 99
Bosch Security Systems | 10/03 | 47775E
Disable/Restart the control panel to activate
today’s window. If you are programming a
window that needs to activate on the same day
that you are programming it, do a disable/restart
after programming.
W# Close Window Start
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to
start the Closing Window. The window goes into
effect at the beginning of the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create
a Closing Window. To program a Closing Window,
Close Early Begin and Close Window Stop must
also be programmed.
If the area is not armed when the Close Window
Start time comes, a warning tone sounds and
PLEASE CLOSE NOW displays at the command
center. To temporarily silence the tone, press the
[ESC] key on the command center. The warning
tone restarts in 10 minutes if the area is not armed.
See the
W# Close Early Begin
prompt in this
section for report feature explanations.
W# Close Window Stop
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to
end the Closing Window. The window stops at the
end of the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create
a Closing Window. To program a Closing Window,
Close Early Begin and Close Window Start must
also be programmed.
If the area is not armed by the time the Close
Window Stop time expires, the control panel
generates a Fail to Close Report if enabled in Fail To
Close.
Closing Reports generated between the Close
Window Start time and Close Window Stop time
can be suppressed by programming
Disable O/C in
Window
Yes. See the
W# Close Early Begin
prompt for other report feature explanations.
Do not use a time of 23:59 as a window stop time
unless the window continues on the next day at
00:00. Fail to Close Reports are not sent, and the
Auto Close feature does not work for windows that
stop at 23:59.
Do not program a single window to cross the
midnight boundary. The window stop time must be
later than the window start time. To program a
window that effectively crosses the midnight
boundary, you must program two windows.
For example, to program windows for an area that
closes between 11:30 PM and 12:30 AM, five days a
week, use two windows as shown in Table 34.
Table 34: W# Close Window Stop Programming Example
Open Close
W# Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
1
S M T W T F S
22 : 00 23 : 30 23 : 59
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
2
S M T
W T F S
00 : 00 00 : 00 00 : 30
Yes No
1 2 3 4
1 2 3 4 5 6 7 8

Table of Contents

Other manuals for Bosch D7412G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D7412G and is the answer not in the manual?

Bosch D7412G Specifications

General IconGeneral
Partitions8
Power Supply16.5 VAC, 40 VA
User Codes99
Users99
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (32°F to +120°F)

Related product manuals