EasyManua.ls Logo

Bosch D7412G Program Entry Guide

Bosch D7412G
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN EN | 46
Bosch Security Systems | 10/03 | 47775E
A# Perimeter O/C
Default: No
Selection:
Yes or No
Yes This area can send Perimeter Opening and
Closing Reports.
No This area cannot send Perimeter Opening and
Closing Reports.
This item determines if this area can send Perimeter
Instant and Perimeter Delay Closing Reports and
normal Opening Reports to the central station.
Opening/Closing Windows do not suppress this
event.
Modem format reporting is required. Some
central station automation systems cannot
process these reports.
2.10 Command Center
This programming module contains three
programming categories: Cmd Cntr Assignment,
Area Text, and Custom Function.
2.10.1 Cmd Cntr (Command Center) Assignment
This programming category assigns a command
center to an area and determines if the command
center is supervised. The command centers are
connected to the control panel using a two-wire
serial data interface bus (SDI bus). This bus can
support up to eight supervised command centers,
each with its own unique command center address
(CC) and corresponding DIP switch address settings.
Should the command centers not be supervised, you
can install multiple command centers with the same
DIP switch address setting for up to 32 unsupervised
command centers.
Cmd Center
Default: 1
Selection:
1 to 8
DIP Switch Setting
SDI
CC#
Address
Number123456
1 1 ON ON ON ON -- ON
22 OFF ON ON ON -- ON
3 3 ON OFF ON ON -- ON
4 4 OFF OFF ON ON -- ON
5 5 ON ON OFF ON -- ON
6 6 OFF ON OFF ON -- ON
7 7 ON OFF OFF ON -- ON
8 8 OFF OFF OFF ON -- ON
Enter the command center (CC) number for the SDI address you are programming. This number corresponds to
the DIP switch address settings shown.

Table of Contents

Other manuals for Bosch D7412G

Questions and Answers:

Bosch D7412G Specifications

General IconGeneral
Partitions8
Power Supply16.5 VAC, 40 VA
User Codes99
Users99
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (32°F to +120°F)

Related product manuals