S## Door 1 [through 8]
Default: No
Yes
Secure Door #.
19
Secure Door: This function
emulates the SECURE? 12345678
command center function for
securing a door.
Selection: Yes or No
Enable the sked to return the doors
programmed Yes to the secured state.
No
Do not secure Door
#.
S## Door 1 [through 8]
Default: No
Yes
Lock Door #.
20
Lock Door: This function returns
an Unlocked (Function 18) or
Secured (Function 19) door to a
normal locked door state.
Selection: Yes or No
Enable the sked to lock the doors
programmed Yes and return them to
the normal Door Mode.
No
Do not lock Door #.
S## Door 1 [through 8]
Default: No
Yes
Enable the reporting
of Access Granted
Events for Door #.
21
Access Authority Events On:
The control panel can log Access
Granted Events when a valid
token, RTE, REX, or Unlock Door
Event is detected for a specific
door. These events can be directed
to print at a local printer or report
remotely through phone routing.
This sked enables Access Granted
Events to be reported for Door #.
Selection: Yes or No
This parameter enables the reporting
of Access Granted Events for Door #.
No
Do not enable the
reporting of Access
Granted Events for
Door #.
S## Door 1 [through 8]
Default: No
Selection: Yes or No
Yes
Disable the
reporting of Access
Granted Events for
Door #.
22
Access Authority Events Off:
The control panel can log Access
Granted Events when a valid
token, RTE, REX, or Unlock Door
Event is detected for a specific
door. These events can be directed
to print at a local printer or report
remotely through phone routing.
This sked disables Access Granted
Events to be reported for Door #.
This parameter disables the reporting
of Access Granted Events for Door #.
No
Do not disable the
reporting of Access
Granted Events for
Door #.
S## Door 1 [through 8]
Default: No
Yes
Enable the reporting
of No Entry Events
for Door #.
23
No Entry Events On: The control
panel can log No Entry Events
when an invalid token is detected
for a specific door. No Entry
Events include No Entry-Secured,
No Entry-Interlock, No Entry-
Unknown ID, and No Entry-Level.
These events can be directed to
print at a local printer or report
remotely through phone routing.
This sked enables No Entry Events
to be reported for Door #.
Selection: Yes or No
This parameter enables the reporting
of No Entry Events for Door #.
No
Do not enable the
reporting of No
Entry Events for
Door #.

Table of Contents

Other manuals for Bosch D7412G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D7412G and is the answer not in the manual?

Bosch D7412G Specifications

General IconGeneral
Partitions8
Power Supply16.5 VAC, 40 VA
User Codes99
Users99
Communication FormatsContact ID, SIA
Operating Temperature0°C to +49°C (32°F to +120°F)