21
IPL
TE-3000S/4000F/4500F Dealer's Manual
Via CF card (to send the IPL data to register)
Via CF card (to send the IPL data to CF card)
Operation
1. Turn OFF the register.
2. Open the CF card slot cover and insert the CF card securely.
(Please check that the CF card is vacant. Refer to the “System utility section in PGM7”.)
3. Turn to PGM mode.
4. Enter “7” and press <SUBTOTAL>.
5. Enter “170” and press <SUBTOTAL>.
6. Enter “49” and press <CASH>.
(In case of quitting, press <SUBTOTAL> instead of <CASH>.)
7. Turn OFF the register and pull out the CF card.
CF card
CF card
Operation
1. Set the mode switch to PGM position and turn off the power switch.
(Refer page 14 of this manual for the location of the power switch.)
2. Open the CF card slot door and insert the CF card securely.
3. While holding down the <JOURNAL FEED>, turn on the register.
4. Release <JOURNAL FEED> after the register shows “INIT”.
5. Enter “44449999” and press <SUBTOTAL>.
6. Enter “20” and press <SUBTOTAL>.
Never plug/unplug the CF card during IPL.
Never plug/unplug the CF card during IPL.