59
Program 3
TE-3000S/4000F/4500F Dealer's Manual
Department key/flat-PLU key/PLU program (Batch feature programming)
Programming procedure
Department/flat-PLU key
PLU
Program data
To another department/flat-PLU key
Description Choice Program code Initial value
Single item control: (Not for PLU 2nd@)
Normal receipt = 0, Single item receipt = 3
Price change registration is enable.
(Only effective for scanning PLU linked to this department)
Multiplication registration is enable.
(Only effective for scanning PLU linked to this department)
Compulsory input unit price manually.
(Only effective for scanning PLU linked to this department)
Normal/condiment/preparation (Not for PLU 2nd@ nor department)
Normal item = 0, Condiment = 1, Preparation = 2
Disable operation in RF/REG– mode.
(Not for PLU 2nd@)
Disable operation in REG 2 mode.
(Not for PLU 2nd@)
Disable operation in REG 1 mode.
(Not for PLU 2nd@)
Taxable status:
See the next page.
Enable 0 unit price.
Enable negative price. (Not for PLU 2nd@)
Hash (Not for PLU 2nd@)
Registration status: (Not for PLU 2nd@)
• Prohibit scale registration = 0
• Allow electronic scale registration only = 1
• Allow manual and electronic scale registration = 2
• Allow manual and non scale registration = 3
Low digit limitation (LDL) for manually entered unit price.
(Not for PLU 2nd@)
Multiple validation: (Not for PLU 2nd@)
(If “No”, validation is allowed only one time.)
Print difference between the normal price and reduced price.
(Not for PLU 2nd@)
Open PLU (Only for PLU)
Commission 1 (Not for PLU 2nd@)
Commission 2 (Not for PLU 2nd@)
Compulsory number of condiment/preparation PLU input.
(Not for PLU 2nd@)
a
b
c
a
b
c
a
b
c
a
b
c
a
b
:
D
12
:
(a+b+c)
D
11
:
D
10
:
(a+b+c)
D
9
::
D
8
D
7
:
(a+b+c)
D
6
:
D
5
:
D
4
:
(a+b+c)
D
3
:
(a+b)
D
2
:
D