Service Check Function SiBE121123_A
139 Service Diagnosis
3. Service Check Function
3.1 RA Indoor Unit
3.1.1 ARC466 Series Remote Controller
Check Method 1 1. When the timer cancel button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press the timer cancel button repeatedly until a long beep sounds.
îš„
The code indication changes in the sequence shown below.
<ARC466A1, A6, A9>
<ARC466A2>
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try the check
method 2. (→ Refer to page 140.)
No. Code No. Code No. Code
1 00 13 C7 25 UA
2 U4 14 A3 26 UH
3 L5 15 H8 27 P4
4 E6 16 H9 28 L3
5 H6 17 C9 29 L4
6 H0 18 C4 30 H7
7 A6 19 C5 31 U2
8 E7 20 J3 32 EA
9 U0 21 J6 33 AH
10 F3 22 E5 34 FA
11 A5 23 A1 35 H1
12 F6 24 E1 36 P9
No. Code No. Code No. Code
1 00 14 C7 27 UA
2 U4 15 A3 28 UH
3 L5 16 H8 29 P4
4 E6 17 H9 30 L3
5 H6 18 C9 31 L4
6 H0 19 C4 32 H7
7 A6 20 C5 33 U2
8 E7 21 CE 34 EA
9 U0 22 J3 35 AH
10 F3 23 J6 36 FA
11 A5 24 E5 37 H1
12 F6 25 A1 38 P9
13 A9 26 E1
(R14220)
< ARC466 Series >
Timer cancel button

Table of Contents

Other manuals for Daikin 2AMX40G3V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 2AMX40G3V1B and is the answer not in the manual?

Daikin 2AMX40G3V1B Specifications

General IconGeneral
BrandDaikin
Model2AMX40G3V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals