SiBE041101 Outdoor Unit - RK(X)S20/25/35J2V1B
Removal Procedure 186
2.6 Removal of Four Way Valve
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Pull out the electronic
expansion valve coil.
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the
compressor.
(R7233)
Electronic
expansion
valve coil
(R7234)
Terminal cover
V
W
U
(R7235)
Red (U)
Yellow (V) Blue (W)