Function of RA Indoor Unit SiBE121135_A
93 Function and Control
1.15 Inverter POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail When the [POWERFUL] button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A = 40 ~ 90 rpm (depending on the model)
Ex: POWERFUL operation in cooling
Note: For Floor Standing Type: FVXG Series
POWERFUL operation is only available in RADIANT 1 (RADIANT operation with heating), it is
not available in RADIANT 2 (RADIANT operation only).
Operation mode Fan speed Target temperature
COOL H tap + A rpm 18°C
DRY Dry rotating speed + A rpm Lowered by 2 ~ 2.5°C
HEAT / RADIANT 1 H tap + A rpm 30 ~ 32°C
FAN H tap + A rpm
AUTO Same as cooling / heating in
POWERFUL operation
The target temperature is kept
unchanged.
(R13571)
Target temp.
Fan
A rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes. also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super multi NX E Series and is the answer not in the manual?

Daikin Super multi NX E Series Specifications

General IconGeneral
BrandDaikin
ModelSuper multi NX E Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals