SiBE121135_A Cooling Only
Specifications 18
50 Hz, 230 V
Note: The data are based on the conditions shown in the table below.
Model 4MKS75F2V1B 5MKS90E2V3B
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC45DXD 2YC63BXD
Motor Output W 1,380 1,920
Refrigerant Oil
Model FVC50K FVC50K
Charge L 0.65 0.75
Refrigerant
Type R-410A R-410A
Charge kg 2.3 2.95
Airflow Rate
H
m³/min
52.7 54.5
M49.4—
L43.546
H
cfm
1,861 1,924
M 1,744 —
L 1,536 1,624
Fan
Type Propeller Propeller
Motor Output W 53 66
Running Current A H: 0.20 / M: 0.16 / L: 0.10 H: 0.97 / L: 0.69
Power Consumption W H: 70 / M: 58 / L: 36 H: 86 / L: 55
Starting Current A 6.2 11.4
Dimensions (H × W × D) mm 735 × 936 × 300 770 × 900 × 320
Packaged Dimensions (H × W × D) mm 797 × 992 × 390 900 × 925 × 390
Weight (Mass) kg 57 69
Gross Weight (Gross Mass) kg 61 78
Sound Pressure Level dB(A) 48 48
Sound Power Level dB 61 62
Piping
Connection
Liquid mm
φ
6.4
×
4
φ
6.4
×
5
Gas mm
φ
9.5
×
2,
φ
12.7
×
1,
φ
15.9
×
1
φ
9.5
×
2,
φ
12.7
×
1,
φ
15.9
×
2
Drain mm
φ
18.0
φ
25.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
No. of Wiring Connection 3 for Power Supply, 4 for Interunit Wiring 3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m 60 (for Total of Each Room) 75 (for Total of Each Room)
m 25 (for One Room) 25 (for One Room)
Amount of Additional Charge g/m Chargeless 20 (65 m or more)
Max. Installation Height Difference
m 15 (between Indoor Unit and Outdoor Unit) 15 (between Indoor Unit and Outdoor Unit)
m 15 (between Indoor Units) 7.5 (between Indoor Units)
Drawing No. 3D056453 3D063120
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
5 m (4MKS75F2V1B)