SiBE121135_A Function of RA Indoor Unit
Function and Control 94
1.16 Multi-Colored Indicator Lamp / TIMER Lamp
Features Wall Mounted Type: FTXG Series
Current operation mode is displayed in color of the lamp of the indoor unit. Operating status can
be monitored even in automatic operation in accordance with the actual operation mode.
The lamp color changes according to the operation.
∗ AUTO ........................................................Red / Blue
∗ DRY ..........................................................Green
∗ COOL........................................................Blue
∗ HEAT ........................................................Red
∗ FAN...........................................................White
∗ TIMER.......................................................Orange
Brightness
Setting
The brightness of the multi-colored indicator lamp can be adjusted L (low), H (high), or OFF.
1. Press the center of the [Temp] button and the [Mode] button at the same time.
5C is displayed on the LCD.
2. Select L (light) with the [Temp]
or button.
3. Press the [Mode] button to enter the brightness setting mode.
(R15294)
Multi-colored indicator lamp /
TIMER lamp
(R11669)
(R11911)
(R11912)