Enter/Exit Programming Mode
132
PowerScan™ PD953X/PBT950X/PM950X
Standard 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Standard 2 of 5 Length
Control. Length 2 is the maximum label length if in Variable Length Mode,
or the second fixed length if in Fixed Length Mode. Length includes the bar
code’s check and da
ta characters.
The length can be set from 1 to 50 char
acters. A setting of 0 specifies to
ignore this length (only one fixed length).
Table 11 provides examples for setting Length 2. See page 282 for detailed
instructions on setting this feature.
Table 11. Standard 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (pad with
leading zeroes)
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CS2L2
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic PowerScan PD953X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD953X and is the answer not in the manual?

Datalogic PowerScan PD953X Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD953X
CategoryBarcode Reader
LanguageEnglish

Related product manuals